8-15 kVA at 0.9 power factor
200-240 VAC with neutral or with optional input transformer
50/60 Hz
Double conversion
Compact tower
MODELS (8-15 KVA) |
DIMENSIONS (H x W x D, INCHES) |
WEIGHT (LBS) |
| 9155, 2-high with (1) battery module | 32.2 x 12 x 33.7 | 352 |
| 9155, 3-high with (2) battery module | 47.8 x 12 x 33.7 | 590 |
| 9155, 3-high with (1) battery module and (1) transformer module | 47.8 x 12 x 33.7 | 558 |
| GENERAL | |
| TOPOLOGY | Double-conversion |
| COLOR | Black |
| RATING (VA/WATTS) | Up to 15000/13500 |
| DIAGNOSTICS | Full system self-test at startup |
| UPS BYPASS | Automatic on overload or UPS failure |
| WARRANTY | Two-year factory warranty |
| CONTENTS (SHIPS WITH THE FOLLOWING ITEMS) | 1 ready-to-go UPS, software suite CD, user guide |
| EFFICIENCY | Up to 91% |
| ELECTRICAL INPUT | |
| CONNECTION | Hardwired - see manual for terminal block layout |
| FREQUENCY | 50/60 Hz (45 to 65 Hz) |
| FREQUENCY RANGE | 45 to 65 Hz |
| INPUT POWER FACTOR | P.F >0.99 typical, >0.96 frequency converter |
| GENERATOR COMPATABILITY | Yes |
| ELECTRICAL OUTPUT | |
| OUTPUT VOLTAGE | 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement |
| OUTPUT RECEPTACLES | (1) PDM |
| ON UTILITY VOLTAGE REGULATION | Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
| ON BATTERY VOLTAGE REGULATION | Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
| OVERLOAD CAPACITY | 150% for 5 sec / 125% for 1 min (online), 110% for 10 min |
| VOLTAGE WAVE SHAPE (ON BATTERY) | Sine Wave |
| TRANSFER TIME | 0 ms |
| BATTERY | |
| BATTERY MANAGEMENT | ABM technology |
| BATTERY TYPE | 9Ah, sealed, lead-acid, maintenance-free |
| BATTERY REPLACEMENT | Field-replaceable |
| START ON BATTERY | Allows start of UPS without utility input |
| RECHARGE TIME | Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge |
| COMMUNICATIONS | |
| USER INTERFACE | LCD Display with blue backlight |
| LEDS | (4) LEDs for notice and alarm |
| AUDIBLE ALARMS | Yes |
| COMMUNICATION PORTS | (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input |
| COMMUNICATION SLOT | (2) X-Slot communication bays |
| POWER MANAGEMENT SOFTWARE | Bundled Software Suite CD |
| ENVIRONMENTAL & STANDARDS | |
| AUDIBLE NOISE | <53dBA at 1 meter (noise less room) typical |
| OPERATING TEMPERATURE | 10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25°C |
| STORAGE TEMPERATURE | -15°C to +25°C |
| RELATIVE HUMIDITY | 0-95%, non condensing |
| CERTIFICATIONS | |
| SAFETY CERTIFICATIONS | UL1778 5th Edition, CSA C22.2 No. 107.3-14, NOM-NYCE |
| EMC COMPLIANCE | 47 CFR Part 15/ICES-003 Class A |
| QUALITY | ISO 9001:2015, ISO 14001:2004 |
| SURGE | ANSI C62.41 Category B3, IEC 61000-4-5 |
| MARKINGS | cULus, NOM-NYCE |