Tripp Lite series SmartOnline 5000VA 4500W 208V Online Double-Conversion UPS - L6-30P, 2 L6-20R, 2 L6-30R, Hardwired Output, Network Card, Extended Run, 3U Rack/Tower
| Product Name |
Eaton Tripp Lite series SmartOnline UPS
|
| Catalog Number |
SU5000RT
|
| UPC |
786689811723
|
| Product Length/Depth |
25.04 in
|
| Product Height |
5.12 in
|
| Product Width |
17.32 in
|
| Product Weight |
114.02 lb
|
| Compliances |
FCC Compliant
CE Marked RoHS FCC Class A ENERGY STAR certified REACH |
| Certifications |
NOM
IEC/EN 62040-2 CSA 22.2 UL 1778 cTUVus |
| Global Catalog |
SU5000RT
|
| Battery replacement |
EBP-1803
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Extended battery capability |
Add up to 4 extended battery modules (EBM). Part number BP180RT
|
| Runtime at full load |
3 min. (4500W)
|
| Runtime at half load |
11 min
|
| High Voltage Transfer to Battery Power |
276V
|
| Low Voltage Transfer to Battery Power |
176V
|
| Output Voltage Regulation (Line Mode) |
+/- 1%
|
| Output Voltage Regulation(Battery Mode) |
+/- 1%
|
| Receptacle |
(2) L6-20R; (2) L6-30R; Hardwire
|
| Topology |
Online/Double-conversion
|
| Wattage |
4500 W
|
| Output waveform |
True sine wave
|
| Output power factor |
0.9
|
| Voltage |
208 V
|
| Output nominal voltage |
208V default (200/208/220/230/240V)
|
| Output frequency |
50/60 Hz
|
| Number of Outputs L6-20R |
2
|
| Number of Outputs L6-30R |
2
|
| Number of outputs hardwired |
1
|
| Current Crest Ratio |
3:1
|
| Input connection |
Hardwire; L6-30P
|
| Input cord length |
10 ft
|
| Input nominal voltage |
200 VAC/208 VAC/220 VAC/230 VAC/240 VAC
|
| Input voltage range |
200-240V
|
| Input power factor |
>0.99 typical
|
| AC suppression joule rating |
390
|
| Input Circuit Breakers |
Recommended 30A upstream
|
| Ethernet interface |
Yes
|
| Includes network card |
Yes
|
| Software compatibility |
PowerAlert
|
| Altitude |
<1000m for nominal power, 10% power degrading every 1000m (up to 3000m)
|
| Noise level |
<45 dB at 1 meter
|
| Relative humidity |
0-95% non-condensing
|
| Storage Temperature |
With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Form factor |
Rack/tower
|
| Rack size |
3U
|
| Rack mounting kit |
Yes
|
| Efficiency at max. load |
93%
|
| Switch configuration |
RPO / ROO
|
| Phase (input) |
Single-phase
|
| Surge protection |
Yes
|
| Internal bypass |
Yes
|
| Package contents |
|
| Total Harmonic Distortion |
< 2% THDV on linear load; < 5% THDV on non-linear load
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| Green Energy-Saving Features |
High efficiency economy mode operation
|
| Standard factory warranty |
|
| Extended service plans |
|